The words of localization microscopy as SMAPpy uses them, with the other names they go by.
Every page explains a word where it first uses it, in a line; this page has them all in one place, in the same wording. The first name is the one SMAPpy's buttons and pages use; the names in brackets are the ones found in papers and in other software.
Localizations
localization (also called a spot, an event or a detection): one molecule's position, fitted in one camera frame – one row of the table.
attribute (also called a column, or a field in SMAP): one value every localization carries – its x, its photons, its track id, a value derived from others – what the localization table stores in one column of a file.
frame: one camera image of the movie.
blink (also called an on-event): the consecutive frames in which one fluorophore stays on.
dark time (also called the off-time): how many frames a fluorophore stays dark between two blinks.
burst (also called a dark-time-merged count, SMAP's locsdf): the blinks joined across dark times up to a set length – with the length chosen well, the blinks of one molecule.
DNA-PAINT (points accumulation for imaging in nanoscale topography): a fluorescent imager strand in solution binds to and unbinds from a docking strand on the target, so each binding site blinks again and again, without bleaching.
DNA origami: DNA folded into a chosen shape – a flat rectangle of about 100 × 70 nm, say – with docking strands for DNA-PAINT where they are wanted, so the sites' arrangement is known to a nanometre: the test sample of DNA-PAINT.
binding event (in Picasso, a linked localization): the localizations of one binding of an imager to a site – in a region, every localization joined across gaps of a few frames.
bright time (also called the binding time, or len in Picasso): how many frames a binding event lasts, its first to its last.
qPAINT (quantitative PAINT): counting the binding sites of a region from how often it is bound – the rate of its binding events, the qPAINT index, over the rate of a single site, the influx.
merge blinks (also called grouping or linking): combine the localizations in consecutive frames that come from one blinking event into one localization, with the photons added and a better precision.
on-time: how many frames a blink lasts – n_in_group once blinks are merged.
photons: the light a fit attributes to one localization, in photons rather than camera counts.
background: the photons per pixel that do not come from the molecule.
localization precision (also called localization uncertainty, or the CRLB, Cramér-Rao lower bound; the attribute xy_err_nm): how far a fitted position is expected to lie from the true one, as one standard deviation, computed by the fitter from the photons, the background and the PSF.
NeNA (nearest-neighbour analysis): the precision measured on the data itself, from how far apart the localizations of one molecule in consecutive frames lie.
FRC (Fourier ring correlation): a resolution measure – the finest detail at which two pictures, each made from half of the localizations, still agree.
ground truth: in a simulation, where the molecules really were.
Fitting
PSF (point spread function): the image one point-like emitter makes on the camera; its shape changes with the emitter's z.
fit box (also called ROI size or fitting window): the square of camera pixels cut around each candidate spot and fitted.
MLE (maximum-likelihood estimation): fitting by finding the parameters under which the pixel values seen are the most probable, given the camera's noise.
spline calibration (also called bead calibration, cspline, or an experimental PSF model): a 3D model of the PSF measured from z-stacks of fluorescent beads, from which the Spline 3D fitters read z.
astigmatism: a cylindrical lens in the detection path makes a spot wider in x on one side of the focus and in y on the other, so its shape tells its z.
z: the position along the optical axis, of a 3D localization.
index mismatch (also called refractive-index mismatch or depth-induced aberration): immersion oil and a watery sample bend light differently, so the PSF of a molecule deep in the sample gains a spherical aberration, and its focus moves less than the objective does.
sample index (also called the medium's or the sample's refractive index, n_med): the refractive index of what the molecules sit in – water 1.33, a dSTORM blinking buffer about 1.345, a mounting medium up to the oil's 1.52. It sets the index mismatch and the SAF.
SAF (supercritical-angle fluorescence): light that only a molecule within about a wavelength of the coverslip sends into the objective, at angles beyond the critical one; it makes those molecules brighter.
neural network (also called a deep-learning model): a function with millions of adjustable numbers, adjusted – trained – on examples whose answer is known, here frames simulated with the microscope's PSF, until it gives that answer; then applied to data, it localizes without a fit.
U-Net: a network for images that shrinks a frame step by step to see large structures and grows it back to full size to say something about every pixel, the full-size steps joined to the small ones so fine detail survives. DECODE's localizes this way: an answer for every pixel.
mixture model (also called a Gaussian mixture): a probability distribution that is a sum of several bell curves, each with its weight; DECODE describes where the molecules of a frame are as such a sum, one bell curve a pixel, weighted by the pixel's detection probability.
Jaccard index (also called the Jaccard score): how well a fit finds the molecules of a simulation, the molecules found divided by those found, missed and invented together – 1 when every molecule is found and nothing else, 0 when none is.
Camera
ADU (analog-to-digital units, also called counts or grey values): the camera's raw pixel values.
offset (also called baseline or bias): what a pixel reads with no light, in ADU.
conversion (also called sensitivity, or gain in e-/ADU): photoelectrons per ADU – what turns camera counts into photons.
EM gain (electron multiplication gain): how much an EMCCD amplifies the signal before reading it out; the counts are divided by it on the way to photons.
EMCCD, sCMOS: the two kinds of camera used for single molecules; an EMCCD amplifies the signal before reading it, an sCMOS reads every pixel through its own amplifier.
camera ROI (also called the readout region or crop): the part of the chip the camera read out.
frame time (also called the cycle time or frame interval): the time from one frame to the next – the exposure plus the camera's dead time; where the file does not record it, the exposure stands in for it. A file that records neither (a simulation of an older version, a bare csv) is given one in File > File properties.
The picture
layer: one picture of the localizations with its own filter, colours and render mode; layers are drawn on top of each other.
filter (also called bounds): the lowest and highest values of attributes – photons, precision, frame – that a localization must lie between to be shown and measured.
selection: what a plugin measures – the localizations that pass the layer's filter, inside the drawn ROI and, when the 3D view's slab is used, inside the slab.
render mode: how localizations become a picture – histogram counts them per pixel, Gaussian (fixed) draws each as a blob of one fixed width, Gaussian (precision) as a blob as wide as its precision, diffraction-limited as wide as its fitted spot on the camera's pixels, like a widefield image.
LUT (lookup table, also called a colour map): the colours that pixel values are drawn in, from low to high.
slab: a slice of the sample of fixed thickness in z, in the 3D view.
z-stack (also called a focus series or a volume): camera images of the same field taken with the focus stepped in z, one plane per step.
MIP (maximum-intensity projection): a stack seen as one picture, each pixel the brightest value along its line of sight through the planes.
Drift
drift: the slow movement of the sample against the camera during the acquisition, which smears the picture.
drift correction: estimating the drift over time and subtracting it from every localization.
RCC (redundant cross-correlation): a drift correction that makes a picture of each time window and cross-correlates every pair of them.
COMET: a drift correction that finds the drift curve under which the localizations from different times overlap best, without making pictures.
DME (drift at minimum entropy): a drift correction like COMET that counts each localization by its precision, so imprecise ones pull less.
split-half error bar: the drift estimated again from each half of the field; the halves hold different molecules, so their difference is chance alone and measures how noisy the drift curve is.
fiducial (also called a fiducial marker, or a bead): a bright, still particle on the coverslip – a fluorescent microsphere, a gold particle – seen in nearly every frame, whose apparent movement is the drift.
MINFLUX: localization by a doughnut of light moved around each molecule, to a few nanometres with few photons; Abberior's microscopes record it with no camera, so a localization has a time and no frame.
trace (MINFLUX's tid): the localizations of one molecule measured in a row, before the microscope moves on to the next.
MBM (beam-line monitoring): a MINFLUX microscope's few fixed beads, measured every couple of seconds during the acquisition; Imspector subtracts their mean displacement from every localization.
vibration (also called jitter, or mechanical noise): fast movement of the sample or the optics – from the building, a fan, a pump – that repeats many times a second, faster than drift.
amplitude spectrum (also called the Fourier spectrum, or the FFT): a signal taken apart into sinusoids, the amplitude of each against its frequency; a vibration is a peak.
RMS (root mean square): the square root of the mean of the squares – of a position around its mean, its standard deviation; a sinusoid of amplitude A has an RMS of A / √2.
Allan deviation (also called the two-sample deviation): how much the mean position over a time τ differs from the mean over the next τ, as a standard deviation; over one point it is the point-to-point scatter, and pure noise falls as 1 / √(points averaged) while drift makes it rise.
Regions
ROI (region of interest): a shape – rectangle, circle, polygon or line – drawn in the view, or found or drawn in the ROI manager.
region: a set of localizations measured together – an ROI, or a cluster that an id attribute such as cluster_id names.
id attribute (also called an id column): an attribute of whole numbers that names regions, the localizations sharing a value being one region – cluster_id, tid, track_id. Every value is an id, 0 included; -1 is "in none".
region table: what was measured in a set of regions, a row per region and a column per number.
per-region steps: plugins run once in every region, what each measures kept as that region's row.
cluster: localizations that lie closer to each other than to the rest.
convex hull: the smallest outline without dents that contains a set of localizations – the shape a rubber band stretched around them takes.
radius of gyration (Rg): the typical distance of a cluster's localizations from its centre, the root of their mean squared distance.
DBSCAN (density-based spatial clustering of applications with noise): a clustering in which a localization with enough neighbours within a radius starts or extends a cluster, and the rest are noise.
complete spatial randomness (CSR, also called a Poisson pattern): positions placed independently, every place in the window equally likely – what "not clustered" means in a test.
pair correlation (g(r), also called the pair correlation function or radial distribution function): the number of pairs of localizations at distance r, over what complete spatial randomness gives – 1 for random positions, above 1 at the distances where they cluster.
Ripley's K (and L(r) - r, also called H(r)): the mean number of neighbours within r over the density, and the same made a straight line, 0 for random positions.
local density: how many localizations lie within a radius of a localization – a number per localization, not a region.
Voronoi tessellation (also called a Voronoi diagram): the division of the plane into one cell per localization, the part of the plane closer to it than to any other; a small cell means a dense neighbourhood.
NPC (nuclear pore complex): the eight-cornered ring of proteins in the nuclear envelope, a standard structure for testing labelling and resolution.
labelling efficiency (also called degree of labelling, or effective labelling efficiency): the fraction of the target proteins that carry a label which is detected.
label uncertainty (also called the linkage error): how far a detected label sits from the centre of its protein – the size of the antibody or nanobody and the error of the position together, as a standard deviation.
oligomer (its oligomeric state, or stoichiometry): a complex of a few copies of one protein – a dimer of two, a trimer of three; a monomer is a protein on its own.
nearest-neighbour distance (NND; the k-th NND): the distance from a molecule to the closest other molecule (or to the k-th closest).
Kolmogorov-Smirnov statistic (KS, D): the largest gap between two cumulative distributions – 0 when two sets of numbers are spread alike, 1 when they do not overlap at all.
bootstrap: an error found by repeating the analysis on data made again – resampled from the data, or simulated from the answer (a parametric bootstrap) – and taking the spread of the answers.
Tracking
single-particle tracking (SPT): following single molecules from frame to frame as they move, to measure how they move.
track (also called a trajectory): the localizations of one particle in time order – track_id names them once they are linked.
jump (also called a step or a displacement): how far a particle moved between two frames it was seen in.
memory (also called gap closing, or the gap frames): how many frames in a row a particle may go unseen – dark, dim or badly fitted – and its track still continue.
MSD (mean squared displacement): how far a particle has moved after a lag of k frames, squared and averaged over the track; a straight line in the lag for free diffusion.
diffusion coefficient (D, in µm²/s): how fast a particle spreads by random motion – the MSD grows by 4 D per second in two dimensions.
anomalous exponent (α, alpha): how the MSD grows with the lag, as lag^α: 1 for free diffusion, below 1 for confined or hindered motion, above 1 for directed motion.
diffusive state: a population of particles, or a phase of one particle's track, with one diffusion coefficient – bound and free, say.
hidden Markov model (HMM): a model in which the particle is in one of a few states at any moment, which cannot be seen directly, and jumps between them at fixed rates; what is seen – here, how far it moves – depends on the state. Fitting it gives the states and the rates of switching.
Two colours
splitter (also called a dual-view or image splitter): optics that put two copies of the image, filtered differently, side by side on one camera chip – the two halves of a split frame.
ratiometric: telling dyes apart by how their photons divide between the two halves, rather than by exciting them one at a time.
crosstalk (also called bleed-through or spectral leakage): the part of one dye's light that reaches the channel meant for the other.
registration (also called channel alignment, mapping or chromatic correction): the transformation – shift, rotation, scale and distortion – that takes a position in one half to the same place in the other.
affine transformation: one that keeps straight lines straight and parallel lines parallel – any mix of shift, rotation, scale, mirror and shear.
projective transformation (also called a homography): an affine one plus a perspective, which can make parallel lines meet; what Calibrate transform fits between two cameras or halves of a chip.
Running things
chain (also called a pipeline or a workflow): plugins run one after another as one plugin, their settings saved in a file.
batch: a chain run over many files, one after the other.